Honda CR-V: Fan Controls
Component Location Index
- RADIATOR FAN RELAY
- A/C CONDENSER FAN RELAY
- FAN CONTROL RELAY

-
A/C CONDENSER FAN ASSEMBLY
-
RADIATOR FAN ASSEMBLY
-
ENGINE COOLANT TEMPERATURE
(ECT) SENSOR 1
-
ENGINE COOLANT TEMPERATURE
(ECT) SENSOR 2
Symptom Troubleshooting Index

Circuit Diagram

Radiator Fan High Speed Circuit Troubleshooting
1. Remove the fan control relay from the under-hood
fuse/relay box, and test it.
Is the relay OK?
YES-Go to step 2.
NO-Replace the fan control relay.
2. Measure the voltage between the fan control relay
5P socket terminal No. 5 and body ground.

Is there battery voltage?
YES-Go to step 3.
NO-Replace the under-hood fuse/relay box.
3. Check for continuity between the fan control relay
5P socket terminal No.2 and body ground.

Is there continuity? YES-Replace the under-hood fuse/relay box.
NO-Repair open in the wire between the fan
control relay 5P socket terminal No.2 and body
ground. If the wire is OK, check for poor ground at
G301.
READ NEXT:
Special Tools
Fuel Sender Wrench
Fuel Pressure Gauge Attachment Set
Vacuum/Pressure Gauge, 0-4 in.Hg
Pressure Gauge Adapter
Oil Pressure Hose
A/T Pressure Hose
A/T Low Pressure
Intermittent Failures
The term "intermittent failure" means a system may
have had a failure, but it checks OK now. If the
malfunction indicator lamp (MIL) on the dash does not
come on, check for poor
SEE MORE:
1. Park with the driver’s side closest
to the service station pump.
2. Open the fuel fill door by pulling
on the handle located under the
lower left corner of the dashboard.
3. Remove the fuel fill cap slowly.
You may hear a hissing sound as
pressure inside the tank equalizes.
The
The ceiling light has a three-position
switch: ON, Door Activated, and
OFF. In the Door Activated (center)
position, the light comes on when
you:
Open any door.
Unlock the doors and the tailgate
with the key or remote transmitter.
After all doors and the tailgate are
closed tightl