Honda CR-V: EGR Passage Removal and Installation
Removal
1. Drain the engine coolant.
2. Remove the air cleaner housing.
3. Remove the harness holder (A) from the bracket,
then remove the harness holder bracket (B).

4. Remove the upper radiator hose (A), heater hose
(B), and water bypass hose (C).

5. Remove the air cleaner housing brackets.

6. Disconnect the exhaust gas recirculation (EGR)
valve connector.
7. Remove the EGR passage.

8. Remove the EGR valve.

Installation
1. Install the EGR valve (A) with a new gasket (B).

2. Install the EGR passage (A) with a new gasket (B).

3. Connect the EGR valve connector.
4. Install the air cleaner housing brackets.

5. Install the upper radiator hose (A), heater hose (B),
and water bypass hose (C).

6. Install the harness holder bracket (A), then install
the harness holder (B).

7. Install the air cleaner housing.
8. Refill the radiator with engine coolant, and bleed
the air from the cooling system with the heater
valve open (see step 6).
READ NEXT:
Removal
1. Remove the hood support rod, then use it as shown
to prop the hood in the wide-open position.
2. Remove the bulkhead cover.
3. Disconnect the fan motor connectors (A) and hood
switch conn
For Japan-produced Model
1. Drain the engine coolant.
2. Remove the hood support rod, then use it as shown
to prop the hood in the wide-open position.
3. Remove the bulkhead cover.
4. Remove the co
Component Location Index
RADIATOR FAN RELAY
A/C CONDENSER FAN RELAY
FAN CONTROL RELAY
A/C CONDENSER FAN ASSEMBLY
RADIATOR FAN ASSEMBLY
ENGINE COOLANT TEMPERATURE
(ECT) SENSOR 1
E
SEE MORE:
1. Support the engine with a jack and wood block
under the oil pan.
2. Remove the upper torque rod.
3. Remove the ground cable (A), then remove the side
engine mount bracket (B).
4. Install the side engine mount bracket, then loosely
tighten the new bolt and nut (C), and loosely tighten
the bolt
NOTE:
Make sure the HDS is loaded with the latest software
version.
If you are replacing the PCM after substituting a
known-good PCM, reinstall the original PCM, then do
this procedure.
During the procedure, is any READ DATA, WRITE
DATA, or other data checks fail, note the failure, then
con